ALTOFLOW HFNC with Bubble CPAP
Humidified high-flow oxygen therapy and bubble CPAP for neonatal, paediatric and adult patients, with an integrated turbine and air-oxygen blender.

Select a numbered point for details.
Microprocessor-controlled ventilator for invasive and non-invasive ventilation of adult and paediatric patients, with twelve modes and high-flow oxygen therapy.
As published by the manufacturer. Confirm against the registered labelling before tender submission.
| Patients and modes | |
|---|---|
| Patient type | Adult, paediatric |
| Modes | Volume control (CMV), assist control (volume and pressure), pressure control, PRVC, SIMV/V, SIMV/P, CPAP with pressure support, BIPAP, APRV, inverse ratio ventilation, non-invasive ventilation, high-flow oxygen therapy, paediatric mode |
| Apnoea backup | Backup mode for apnoea |
| Tidal volume setting | Patient weight-based |
| Leak compensation | Yes |
| High-flow oxygen therapy | Via nasal cannula, with FiO₂ control |
| Set-up | Predefined parameters for rapid patient set-up |
| Controls | |
| Tidal volume | 10–2000 mL |
| Volume support | 10–1600 mL |
| Respiratory rate | 5–90 breaths/min |
| I:E ratio | 1:1 to 5:1 |
| Inspiratory time | 0.2–10 s |
| Inspiratory pressure | Up to 80 cmH₂O |
| Pressure | 0–70 cmH₂O |
| Pressure support | 0–40 cmH₂O |
| PEEP / CPAP | Up to 30 cmH₂O |
| Inspiratory peak flow | 4–180 L/min |
| Minute volume | 1–30 L/min |
| Oxygen concentration | 21–100% |
| Inspiratory pause | 0–60% |
| Nebuliser | Integrated, with on/off |
| Other | Flow ramp for pressure, expiratory pause, sigh |
| Monitoring and display | |
| Monitored values | Tidal volume (Vte), minute volume, respiratory rate, I:E ratio, PIP, plateau pressure, mean airway pressure, PEEP, O₂ %, total run hours, battery level |
| Waveforms | Pressure/time, flow/time, volume/time |
| Loops | Pressure/volume, flow/volume, flow/pressure |
| Display | 10.1" colour touchscreen, LCD/TFT; two waveforms in real time; three graphs and two loops (not necessarily simultaneous) |
| Alarms | |
| Patient | Patient disconnected, low/high pressure, low/high minute volume, low tidal volume, high PEEP, high respiratory rate, low/high O₂, set volume reached (pressure control) |
| System | Low inlet air/O₂, sensor failure, system failure, pneumatic, low battery |
| Settings | Full alarm system for all ventilator settings and monitored values; single or dual tone |
| Power and gas | |
| Mains | 220/240 V AC, 50 Hz |
| Battery | Internal, minimum 2 hours |
| Other power | External DC |
| Gas delivery | Soundless compressor, external or integrated unit |
| Gas supply | 45–60 psi compressed air and oxygen |
| Mounting | Trolley for transport |
| Options | Neonatal, humidifiers, capnography |
Source: hildmedical.com, October 2026.
None listed by the manufacturer.
Available from CraftEdge. The manufacturer’s instructions for use specify the parts for each device.
Humidified high-flow oxygen therapy and bubble CPAP for neonatal, paediatric and adult patients, with an integrated turbine and air-oxygen blender.
Bedside monitoring of ECG, SpO₂, NIBP, temperature and respiration, in 12-inch (EGL MP 121) and 15-inch (EGL MP 151) models.
Real-time data from several ventilators or bedside multi-parameter monitors on one screen, with alarms for abnormal values.